4 Mounting

VEGAPULS 63 • 4 … 20 mA/HART two-wire

36511-EN-130228

4 Mounting

4.1 General instructions

With instruments with threaded process fitting, suitable tools must be

applied for tightening the hexagon.

Warning:

The housing must not be used to screw the instrument in! Applying

tightening force can damage internal parts of the housing.

Use the recommended cables (see chapter "Connecting to power

supply") and tighten the cable gland.
You can give your instrument additional protection against moisture

penetration by leading the connection cable downward in front of the

cable entry. Rain and condensation water can thus drain off. This ap-

plies mainly to outdoor mounting as well as installation in areas where

high humidity is expected (e.g. through cleaning processes) or on

cooled or heated vessels.

Make sure that all parts of the instrument exposed to the process, in

particular the active measuring component, process seal and process

fitting, are suitable for the existing process conditions. These include

above all the process pressure, process temperature as well as the

chemical properties of the medium.
You can find the specifications in chapter "Technical data" and on the

nameplate.

4.2 Instructions for installation

The PTFE washer of the antenna encapsulation is also the process

seal. The following must be fulfilled for an effective sealing:
1. Make sure the number of flange screws corresponds to the num-

ber of flange holes

2. Use disc springs to compensate the preload loss of the PTFE

washer

2

1

Fig. 5: Use of disc springs
1 Single disc spring

2 Laminated disc spring

3. Tighten screws with the necessary torque (see chapter "Technical

data")

4. Retighten screws in regular intervals depending on process pres-

sure and temperature

The emitted radar impulses of the radar sensor are electromagnetic

waves. The polarisation plane is the direction of the electrical wave

Screwing in

Moisture

Suitability for the process

conditions

Sealing to the process

Polarisation plane