3 mounting steps with screwed connection – VEGA VEGAWELL 52 4 … 20 mA User Manual

Page 13

Advertising
background image

4

.3 Mounting steps with screwed connection

1

2

3

4

5

6

Fig. 5: Threaded fitting

1

Suspension cable

2

Seal screw

3

Cone bushing

4

Seal cone

5

Threaded fitting

6

Seal

M

ount VEGAWELL 52 with screwed connection as follows:

1

W

eld the welded socket into the vessel top

2

L

ower VEGAWELL 52 to the requested height by means on the

welded socket G1½ A or 1½ NPT on the vessel side

3

I

nsert the suspension cable from below into the open screwed

connection

4

S

lide the seal cone and the cone sleeve over the suspension

cable, fasten manually with the seal screw

5

S

crew the screwed connection into the socket, fasten with SW 30

and then fasten seal screw with SW 19

H

ow to correct the height:

1

L

oosen seal screw with SW 19

2

S

lide seal cone and cone sleeve to the requested position on the

cable

3

F

asten the seal screw

R

emoval is carried out in reverse order.

VEGAWELL

52 • 4 … 20

mA

13

4 M

ounting

35401

-

EN

-111021