VEGA VEGAMIP R61 Receiving unit - Transistor User Manual

Page 20

Advertising
background image

1

2

Fig. 11: Installation with vessel vibrations

1

Anti vibration blocks or rubber buffers

2

Window of non-conductive material, for example, glass, plastic, etc.

Angle
For an optimum switching signal, the two sensors must be adapted to
each other. The accuracy must be in a range of ±5°.

Offset
The two sensors can have an offset of up to < 5 % of the sensor
distance (d) to each other. Example: with a sensor distance of
1000 mm, the two sensors must have an offset of max. 50 mm to each
other.

General rule: the bigger the antenna and the better it focusses, the
more precise the orientation has to be.

5

°

+ -

d

<

d

2

0

Fig. 12: Orientation of the sensors - Angle and offset

Orientation of the sensor

20

VEGAMIP R

61 • - Transistor

4 Mounting

40694

-EN

-120228

Advertising