4

Mounting

4

.1 General instructions

To prevent the float from touching the vessel wall, it can be guided
vertically.

Use two thin vertical rods or two vertically strained wires at a distance
of 306 mm (12 in) which you lead through the holes in the float plate.

Fig. 3: Guidance of the float

The connection cable can influence the float position of the measuring
system and therefore adulterate the measuring result.

If possible, use a light, flexible connection cable and fasten the cable
with a cable holder. In case of considerable height differences of the
float, you should use a light helix cable.

Product movements can influence the measurement. In this case, use
a signal conditioning instrument with adjustable damping to avoid
fluctuations of the measured value.

There is a danger of static charging on the plastic floating body.

Avoid friction

No dry cleaning

Guidance

Connection cable

Product movements

Static charges