2 principle of operation, 3 packaging, transport and storage – VEGA VEGAPULS SR 68 Foundation Fieldbus User Manual

Page 11

Advertising
background image

11

3 Product description

VEGAPULS SR 68 • Foundation Fieldbus

38297-EN-130624

This operating instructions manual applies to the following instrument

versions:

Hardware from 2.1.1

Software from 4.5.0

The scope of delivery encompasses:

Radar sensor

Documentation

– this operating instructions manual

– Test certificate Measurement accuracy, depending on the

instrument VEGAPULS SR 68 (optional)

– Operating instructions manual "DIsplay and adjustment module

PLICSCOM" (optional)

– Supplementary instructions "GSM/GPRS radio module"

(optional)

– Supplementary instructions manual "Heating for display and

adjustment module" (optional)

– Supplementary instructions manual "Plug connector for con-

tinuously measuring sensors" (optional)

– Ex-specific "Safety instructions" (with Ex versions)

– if necessary, further certificates

3.2 Principle of operation

The VEGAPULS SR 68 is a radar sensor for continuous measurement

of bulk solids also under difficult process conditions. It is particularly

suitable for level measurement in high silos and large bunkers.
The instrument is also suitable for applications in liquids.

The antenna of the radar sensor emits short radar pulses with a

duration of approx. 1 ns. These pulses are reflected by the product

and received by the antenna as echoes. The transit time of the radar

pulses from emission to reception is proportional to the distance and

hence to the level. The determined level is converted into an appropri-

ate output signal and outputted as measured value.

3.3 Packaging, transport and storage

Your instrument was protected by packaging during transport. Its

capacity to handle normal loads during transport is assured by a test

based on ISO 4180.
The packaging of standard instruments consists of environment-

friendly, recyclable cardboard. For special versions, PE foam or PE

foil is also used. Dispose of the packaging material via specialised

recycling companies.

Transport must be carried out under consideration of the notes on the

transport packaging. Nonobservance of these instructions can cause

damage to the device.

Scope of this operating

instructions manual

Scope of delivery

Application area

Functional principle

Packaging

Transport

Advertising