background image

By means of the LED indicating board, you can adjust the switching
delay.

Push the two keys (7) and (8) simultaneously for approximately 2 s
until the LED indication flashes.

With the two keys you can select the requested switching delay
according to the following illustration.

The switching delay can be adjusted in seven steps between 100 ms
and 20 s.

200

ms

100

ms

500

ms

1 s 2 s 5 s 20 s

Fig. 35: Adjust switching delay - LED indication flashes

If the indication moves to the right, the switching delay will be longer, to
the left shorter.

The indication returns automatically to the indication of the actual
receiving level after approximately 10 s.

Should the possibility exist, you can simulate a filling between emitting
and receiving unit by using your hand or a metal sheet and check if the
switching point is adjusted correctly. If the relay control lamp changes
the switching condition, then the switching function is correct.

Switching delay