4 Mounting

VEGAPULS 66 enamel • Profibus PA

36529-EN-121011

center of dished or round vessel tops, multiple echoes can arise.

These can, however, be suppressed by an appropriate adjustment

(see chapter "Setup").
If you cannot keep this distance you should carry out a false echo

storage before setup. This applies mainly if buildup on the vessel wall

is expected. In this case, we recommend repeating a false echo stor-

age later with existing buildup.

> 500 mm

(19.69")

Fig. 6: Mounting of the radar sensor on round vessel tops

In vessels with conical bottom it can be advantageous to mount the

sensor in the center of the vessel, as measurement is then possible

down to the lowest point of the vessel bottom.

Fig. 7: Mounting of the radar sensor on vessels with conical bottom

Do not mount the instruments in or above the filling stream. Make sure

that you detect the product surface, not the inflowing product.

Inflowing medium