VEGA VEGABAR 67 Foundation Fieldbus - climate compensated User Manual

Page 54

Advertising
background image

54

10 Supplement

VEGABAR 67 • Foundation Fieldbus - climate compensated

39446-EN-130321

Process conditions
The specifications of the pressure stage and product temperature are used as an overview. The

specifications on the type label are applicable.
Process pressure

Ʋ with measuring ranges 0.1 bar

(1.45 psig) or 0.2 bar (2.9 psig)

max. 15 bar (217.6 psig) or max. 20 bar (290 psig)

12)

Ʋ with meas. ranges from 0.4 bar

(5.8 psig)

max. 25 bar (363 psig)

13)

Pressure stage, process fitting

Ʋ Threaded fitting

316L PN 3, PVDF PN 5

14)

Ʋ Thread

316L PN 25, PVDF unpressurized

Ʋ Lock fitting

Unpressurized

Product temperature

Ʋ Suspension cable

-12 … +100 °C (+10 … +212 °F)

Ʋ Connection tube

-12 … +100 °C (+10 … +212 °F)

Vibration resistance

mechanical vibrations with 4 g and 5 … 100 Hz

15)

With version with connection tube, vibration resistance 1 g. With lengths > 0.5 m (1.64 ft) the tube

must be supported in addition.
Shock resistance

Acceleration 100 g/6 ms

16)

Electromechanical data - version IP 66/IP 67
Cable entry/plug

17)

Ʋ Single chamber housing

– 1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm), 1 x

blind plug M20 x 1.5

or:

– 1 x closing cap ½ NPT, 1 x blind plug ½ NPT

or:

– 1␣x plug (depending on the version), 1␣x blind stopper

M20␣x␣1.5

or:

– 2 x blind plug M20 x 1,5

12)

Limited by the overpressure resistance of the measuring cell.

13)

Limitation by the pressure-tightness of the cable connection.

14)

Limited by the overpressure resistance of the measuring cell.

15)

Tested according to the guidelines of German Lloyd, GL directive 2.

16)

Tested according to EN 60068-2-27.

17)

Depending on the version M12 x 1, according to ISO 4400, Harting, 7/8" FF.