VEGA VEGABAR 54 4 … 20 mA_HART User Manual

Page 54

Advertising
background image

54

10 Supplement

VEGABAR 54 • 4 … 20 mA/HART

36726-EN-130321

Ʋ PMC 316L

PN 10

Ʋ Flange 316L

PN 40

Product temperature depending on the measuring cell seal

12)

Measuring cell seal

Product temperature

FKM (VP2/A)

-20 … +120 °C (-4 … +248 °F)

EPDM (A+P 75.5/KW75F)

-40 … +120 °C (-40 … +248 °F)

FFKM (Kalrez 6375)

-20 … +120 °C (-4 … +248 °F)

FFKM (Perlast G75S)

-15 … +120 °C (-4 … +248 °F)

FFKM (Perlast G75B)

-15 … +120 °C (-4 … +248 °F)

Vibration resistance

mechanical vibrations with 4 g and 5 … 100 Hz tested

according to the regulations of German Lloyd, GL char-

acteristics 2.

Shock resistance

Acceleration 100 g/6 ms

13)

Electromechanical data - version IP 66/IP 67
Cable entry/plug

14)

Ʋ Single chamber housing

– 1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm), 1 x

blind plug M20 x 1.5

or:

– 1 x closing cap ½ NPT, 1 x blind plug ½ NPT

or:

– 1␣x plug (depending on the version), 1␣x blind stopper

M20␣x␣1.5

or:

– 2 x blind plug M20 x 1,5

Ʋ Double chamber housing

– 1 x cable entry M20 x 1.5 (cable: ø 5 … 9 mm), 1 x

blind plug M20 x 1.5; plug M12 x 1 for the external

display and adjustment unit (optional)

or:

– 1 x closing cap ½ NPT, 1 x blind plug ½ NPT, plug

M12 x 1 for the external display and adjustment unit

(optional)

or:

– 1 x plug (depending on the version), 1 x blind plug

M20 x 1.5; plug M12 x 1 for the external display and

adjustment unit (optional)

or:

– 2 x blind stoppers M20 x 1.5; plug M12 x 1 for the

external display and adjustment unit (optional)

Spring-loaded terminals for wire cross-

section

< 2.5 mm² (AWG 14)

12)

With process fitting PVDF, max. 100 °C (212 °F).

13)

Tested according to EN 60068-2-27.

14)

Depending on the version M12 x 1, according to ISO 4400, Harting, 7/8" FF.

Advertising