4 wiring plan, double chamber housing – VEGA VEGAFLEX 66 (-200…+400°C) Profibus PA User Manual
Page 21
Advertising
I²C
Display
1
2
5 6 7 8
3
4
1
2
Fig. 9: Electronics and connection compartment with single chamber housing
1
Plug connector for VEGACONNECT (I²C interface)
2
Spring-loaded terminals for connection of the external indication VEGADIS
61
3
Ground terminal for connection of the cable screen
4
Spring-loaded terminals for voltage supply
I2C
Display
1
1
2
5
6
7
8
Fig. 10: Wiring plan, single chamber housing
1
Voltage supply/Signal output
5.4 Wiring plan, double chamber housing
The following illustrations apply to the non-Ex as well as to the Ex-ia
version.
Electronics and connec-
tion compartment
Wiring plan
VEGAFLEX
66 • Profibus PA
21
5 Connecting to power supply
34175
-
EN
-100426