6 switch-on phase – VEGA VEGABAR 51 4 … 20 mA User Manual

Page 20

Advertising
background image

20

5 Connecting to power supply

VEGABAR 51 • 4 … 20 mA

36712-EN-130321

1 2 3 4

6

3

4

1

2

5

Fig. 13: Connection of the sensor in the housing socket
1 Brown

2 Blue

3 Yellow

4 White

5 Shielding

6 Breather capillaries

1

1 2

4...20mA

Display

Fig. 14: Wiring plan external electronics
1 Voltage supply/Signal output

5.6 Switch-on phase

After connecting VEGABAR 51 to power supply or after a voltage

recurrence, the instrument carries out a self-check for approx. 30

seconds:

Internal check of the electronics

Indication of the instrument type, the firmware as well as the sen-

sor TAGs (sensor designation)

Output signal jumps briefly (approx. 10 seconds) to the set fault

current

Terminal compartment,

housing socket

Wiring plan external

electronics

Switch-on phase