10 Supplement

VEGABAR 51 • 4 … 20 mA

36712-EN-130321

Ʋ Ex-ia instrument

14 … 30 V DC

Operating voltage with illuminated display and adjustment module

Ʋ Non-Ex instrument

20 … 36 V DC

Ʋ Ex-ia instrument

20 … 30 V DC

Permissible residual ripple

Ʋ < 100 Hz

U

ss

< 1 V

Ʋ 100 Hz … 10 kHz

U

ss

< 10 mV

Load

see diagram

1000

727

500

250

18

16

14

20

22

24

26

28

30

32

34

36

Ω

V

3

1

2

Fig. 20: Voltage diagram
1 Voltage limit Ex-ia instrument

2 Voltage limit non-Ex/Ex-d instrument

3 Operating voltage

Electrical protective measures
Protection rating

Ʋ Housing, standard

IP 66/IP 67

15)

Ʋ Aluminium and stainless housing

(optionally available)

IP 68 (1 bar)

16)

Ʋ Process component in IP 68 version IP 68 (25 bar)

Ʋ External housing

IP 65, IP 66/IP 68 (0.2 bar)

Overvoltage category

III

Protection class

II

Approvals
Instruments with approvals can have different technical data depending on the version.
For that reason the associated approval documents of these instruments have to be carefully

noted. They are part of the delivery or can be downloaded under www.vega.com via "VEGA Tools"

and "serial number search" as well as via "Downloads" and "Approvals".

10.2 Dimensions

The following dimensional drawings represent only an extract of the possible versions. Detailed

15)

Instruments with gauge pressure measuring ranges cannot detect the ambient pressure when submerged, e.g.

in water. This can lead to falsification of the measured value.

16)

Only with instruments with absolute pressure ranges.