6 Set up with the indicating and adjustment module

VEGAPULS 66 • 4 … 20 mA/HART - four-wire

36520-EN-121011

– Strong spout generation

– Very agitated surface, foam generation

Dosing vessel:

Setup: all vessel sizes possible

Product speed:

– Fast filling and emptying

– Vessel is very often filled and emptied

Vessel: narrow installation situation

Process/measurement conditions:

– Condensation, buildup on the antenna

– Foam generation

Standpipe:

Product speed: very fast filling and emptying

Vessel:

– Vent hole

– Joins like flanges, weld joints

– Shifting of the running time in the tube

Process/measurement conditions:

– Condensation

– Buildup

Bypass:

Product speed:

– Fast up to slow filling with short up to long bypass tube possible

– Often the level is hold via a control facility

Vessel:

– Lateral outlets and inlets

– Joins like flanges, weld joints

– Shifting of the running time in the tube

Process/measurement conditions:

– Condensation

– Buildup

– Separation of oil and water possible

– Overfilling into the antenna possible

Plastic tank:

Vessel:

– Measurement fix mounted or integrated

– Measurement depending on the application through the vessel

top

– With empty vessel, the measurement can be carried out

through the bottom

Process/measurement conditions:

– Condensation on the plastic ceiling

– In outside facilities water and snow on the vessel top possible

Transportable plastic tank:

Vessel:

– Material and thickness different

– Measurement through the vessel top

Process/measurement conditions:

Advertising