VEGA VEGAPULS WL 61 Profibus PA User Manual

Page 15

Advertising
background image

15

4 Mounting

VEGAPULS WL 61 • Profibus PA

38062-EN-121011

> 200 mm

(7.87")

Fig. 8: Vertical mounting on the wall via the mounting strap with length 170 mm

Some measuring points have only very little space between ceil-

ing and water surface. In such cases, for example in closed storm

overflow basins, horizontal mounting of the sensor is recommended.

The radar impulses must be directed via a 45° reflector - for example

a stainless steel sheet - to the water surface.

> 50 mm

(1.97")

45°

Fig. 9: Horizontal mounting with a mounting strap of length 170 mm with reflec-

tor provided by the customer

Information:

With this mounting arrangement, the reference plane mentioned in

chapter "Technical data" no longer applies. There is an offset that

must be taken into account for the adjustment. Note the distance

measured at min. level with the reflector, for example 2.5 m. Enter

this value as min. adjustment/measuring range begin. Determine the

difference between the min. and max. level, for example 1 m. The dis-

tance for the max. adjustment results from 2.5 m - 1 m = 1.5 m. Enter

this value as max. adjustment/measuring range end.

Advertising