VEGA VEGAPULS 61 (≥ 2.0.0 - ≥ 4.0.0) Modbus and Levelmaster protocol User Manual

Page 35

Advertising
background image

35

6 Set up the sensor with the indicating and adjustment module

VEGAPULS 61 • Modbus and Levelmaster protocol

41361-EN-121011

Product speed:

– Fast to slow filling possible

– Vessel is very often filled and emptied

Vessel:

– Socket available

– Large agitator blades of metal

– Vortex breakers, heating spirals

Process/measurement conditions:

– Condensation, buildup by movement

– Strong spout generation

– Very agitated surface, foam generation

Dosing vessel:

Setup: all vessel sizes possible

Product speed:

– Fast filling and emptying

– Vessel is very often filled and emptied

Vessel: narrow installation situation

Process/measurement conditions:

– Condensation, buildup on the antenna

– Foam generation

Standpipe:

Product speed: very fast filling and emptying

Vessel:

– Vent hole

– Joins like flanges, weld joints

– Shifting of the running time in the tube

Process/measurement conditions:

– Condensation

– Buildup

Bypass:

Product speed:

– Fast up to slow filling with short up to long bypass tube possible

– Often the level is hold via a control facility

Vessel:

– Lateral outlets and inlets

– Joins like flanges, weld joints

– Shifting of the running time in the tube

Process/measurement conditions:

– Condensation

– Buildup

– Separation of oil and water possible

– Overfilling into the antenna possible

Plastic tank:

Vessel:

– Measurement fix mounted or integrated

– Measurement depending on the application through the vessel

top

– With empty vessel, the measurement can be carried out

through the bottom

Advertising