VEGA VEGAPULS 65 (≥ 2.0.0 - ≥ 4.0.0) HART and accumulator pack User Manual

Page 56

Advertising
background image

56

11 Supplement

VEGAPULS 65 • HART and accumulator pack

40932-EN-121011

Ʋ Button outside on the housing

Switching on and off

Integrated clock
Date format

Day.Month.Year

Time format

12 h/24 h

Time zone Ex factory

CET

Measurement electronics temerature
Resolution

1 °C (1.8 °F)

Accuracy

±1 °C (1.8 °F)

External battery charger
Mains voltage

100 … 240 V AC

Output voltage

24 V DC

Output current (shortcircuit proof) max. 500 mA
Load current limitation

70 mA

DC plug (inside plus, outside minus)

2.1 mm

Integrated accumulator
Type

Lithium ions

Voltage

14.8 V

Accumulator capacity

4.7 Wh

Charging period from 0 % to 100 %

approx.

4 h

Operating time after 10 min. charging of

0 %

> 3 h

Operating time in mode 4 (sensor per-

manently on) with completely charged

accumulator

> 60 h

Temperature range

Ʋ Charge accumulator

0 … +45° C (+32 … +167 °F)

Ʋ Accumulator operation

-20 … +60° C (-4 … +140 °F)

Temperature derating accumulator capacity

Ʋ +25° C (+77 °F)

100 %

Ʋ -10° C (+14 °F)

50 %

Electrical protective measures
Protection, depending on housing version

Ʋ Plastic housing

IP 66/IP 67

Ʋ Aluminium housing, stainless steel

housing - investment casting, stain-

less steel housing - electro-polished

IP 66/IP 68 (0.2 bar)

4)

Overvoltage category

III

Protection class

III

4)

The prerequisites for maintaining the protection rating are a suitable cable as well as correct mounting.

Advertising