3 Product description

VEGAFLEX 83 • 4 … 20 mA/HART - four-wire

41835-EN-130314

The instrument can be supplied in two different electronics versions.

Each electronics version can be identified via the product code on the

type label as well as on the electronics.

Standard electronics with operating voltage 90 … 253 V AC;

50/60 Hz: Typ FX80B.-

Standard electronics with supply voltage 9.6 … 48 V DC;

20 … 42 V AC: Type FX80I.-

The scope of delivery encompasses:

Sensor

Documentation

– this operating instructions manual

– Test certificate measuring accuracy (optional)

– Operating instructions manual "Display and adjustment mod-

ule" (optional)

– Supplementary instructions "GSM/GPRS radio module"

(optional)

– Supplementary instructions manual "Heating for display and

adjustment module" (optional)

– Supplementary instructions manual "Plug connector for con-

tinuously measuring sensors" (optional)

– Ex-specific "Safety instructions" (with Ex versions)

– if necessary, further certificates

3.2 Principle of operation

The VEGAFLEX 83 is a level sensor with coated cable or rod probe

for continuous level or interface measurement, particularly suitable for

applications in the chemical industry.

High frequency microwave pulses are guided along a steel cable or

a rod. Upon reaching the product surface, the microwave pulses are

reflected. The running time is evaluated by the instrument and output-

ted as level.