VEGA VEGAFLEX 83 4 … 20 mA_HART - four-wire PFA insulated User Manual

Page 15

Advertising
background image

15

3 Product description

VEGAFLEX 83 • 4 … 20 mA/HART - four-wire

41835-EN-130314

VEGADIS 61 is an external display and adjustment unit for sensors

with single chamber housing and Ex-d double chamber housing.
It is suitable for measured value indication and adjustment of plics

®

sensors and is connected to the sensor with a four-wire standard

cable up to 50 m (164 ft) long.
You can find further information in the operating instructions "VE-

GADIS 61" (Document-ID 27720).

VEGADIS 62 is suitable for measured value indication and adjustment

of sensors with HART protocol. It is looped into the 4 … 20 mA/HART

signal cable.
You can find further information in the operating instructions "VE-

GADIS 62" (Document-ID 36469).

The PLICSMOBILE T61 is an external GSM/GPRS radio unit for

transmission of measured values and for remote parameter adjust-

ment of plics

®

sensors. The adjustment is carried out via PACTware/

DTM by using the integrated USB connection.
You can find further information in the supplementary instructions

"PLICSMOBILE T61" (Document-ID 36849).

The protective cover protects the sensor housing against soiling and

intense heat from solar radiation.
You will find additional information in the supplementary instructions

manual "Protective cover" (Document-ID 34296).

Screwed flanges are available in different versions according to the

following standards: DIN 2501, EN 1092-1, ANSI B 16.5, JIS B 2210-

1984, GOST 12821-80.
You can find additional information in the supplementary instructions

manual "Flanges according to DIN-EN-ASME-JIS" (Document-ID

31088).

The electronics module VEGAFLEX series 80 is a replacement part

for TDR sensors of VEGAFLEX series 80. There is a different version

available for each type of signal output.
You can find further information in the operating instructions manual

"Electronics module VEGAFLEX series 80".

The display and adjustment module can be optionally replaced by a

display and adjustment module with heating function.
You can hence use the display and adjustment module in an ambient

temperature range of -40 … 70 °C.
You can find further information in the operating instructions "Display

and adjustment module with heating" (Document-ID 31708).

If you mount the VEGAFLEX 83 in a bypass tube or standpipe, you

have to avoid contact to the bypass tube by using a spacer at the

probe end.

External display and

adjustment unit

External display and ad-

justment unit with HART

protocol

External radio unit

Protective cover

Flanges

Electronics module

Display and adjustment

module with heating

Spacer

Advertising