VEGA VEGAFLEX 83 4 … 20 mA_HART - four-wire PFA insulated User Manual
Page 70
70
11 Supplement
VEGAFLEX 83 • 4 … 20 mA/HART - four-wire
41835-EN-130314
0,2 m
(7.874")
0,1 m
(3.937")
0,07 m
(2.756")
1
L
0
-2 mm
(-0.079")
2 mm
(0.079")
15 mm
(0.591")
-15 mm
(-0.591")
Fig. 36: Deviation VEGAFLEX 83 in cable version (coated) in water
1 Dead band - no measurement possible in this area
L Probe length
L
2 mm
(0.079
")
0
-2 mm
(-0.079")
15 mm
(0.591
"
)
-15 mm
(-0.591")
0,35 m
(13.78")
0,2 m
(7.874")
0,2 m
(7.874")
0,05 m
(1.969")
1
1
Fig. 37: Deviation VEGAFLEX 83 in cable version (coated) in oil
1 Dead band - no measurement possible in this area
L Probe length
Repeatability
≤ ±1 mm
Variables influencing measurement accuracy
Specifications for the digital measured value
Temperature drift - Digital output
±3 mm/10 K relating to the max. measuring range or
max. 10 mm (0.394 in)
Additional deviation through electromag-
netic interference acc. to EN 61326
< ±10 mm (< ±0.394 in)
Specifications apply also to the current output