4 Mounting
VEGABAR 83 • Slave sensor for electronic differential pressure
45051-EN-131011
1
2
Fig. 11: Measurement setup for differential pressure measurement of gases in
pipelines
1 VEGABAR 83
1 VEGABAR 83 - Slave sensor
4.6 Interface measurement
The master/slave combination is suitable for interface measurement
Requirements for a functioning measurement are:
•
Vessel with changing level
•
Products with steady densities
•
Interface always between the measurement points
•
Total level always above the upper measurement point
h
1,0
0,8
1
2
Fig. 12: Measurement setup with interface measurement, h = distance between
the two measuring points
1 VEGABAR 83
2 VEGABAR 83 - Slave sensor
Measurement setup