3 electrical connection, 1 connection with vegabox 02 – VEGA VEGAWELL 52 Ship-building User Manual

Page 15

Advertising
background image

15

3 Electrical connection

VEGAWELL 52 • Service tanks (fuel, coolant)

41957-EN-130626

3 Electrical connection

3.1 Connection with VEGABOX 02

Lead the cable glands downward

Close all housing openings

Enable pressure compensation (liquid-tight ventilation filter)

Loop the connection cable into a suitable connection box

Fig. 14: Connection of the VEGAWELL 52 to the connection box

Grounding

In the plastic housing or VEGABOX 02, the screen must be connect-

ed directly to the inner ground terminals. The outer ground terminal on

the housing must have a low impedance connection to the potential

equalization.
Note:

Make sure that the ground cable is applied on bare metal. Varnish can

interrupt the potential equalization connection.

Use in ballast water tanks

On ships, sacrificial anodes of zinc are usually mounted in the ballast

water tanks to protect them against corrosion. Due to a low electro-

Advertising