2 Mounting

VEGAWELL 52 • Service tanks (fuel, coolant)

41957-EN-130626

2 Mounting

2.1 Lateral installation

If there are high temperatures in the vessel, +80 … +110 °C

(+176 … +230 °F), mount VEGAWELL 52 laterally.

X

1

2

Fig. 4: VEGAWELL 52 - lateral mounting with shut-off valve
1 Heating system - Temperature: approx. +110 °C (+230 °F)

2 VEGAWELL 52 - laterally mounted - Temperature: max. +80 °C (+176 °F)

x Offset

Note:

Check if the permissible process temperature of the sensor is suitable

for your application.

Gauge pressure in the vessel influences the measured value. For that

reason there must be a pressure compensation facility in the vessel.

Heating in the vessel

Pressure compensation