11 Supplement
VEGAFLEX 83 • Foundation Fieldbus
44224-EN-130910
L
0
-2 mm
(-0.079
")
2 mm
(0.079
")
15 mm
(0.591
"
)
-15 mm
(-0.591
")
0,2 m
(7.874
"
)
0,08 m
(3.15
"
)
0,04 m
(1.575
")
1
Fig. 53: Deviation VEGAFLEX 83 in rod version in water
1 Dead band - no measurement possible in this area
L Probe length
L
2 mm
(0.079
")
0
-2 mm
(-0.079
")
15 mm
(0.591
"
)
-15 mm
(-0.591
"
)
-10 mm
(-0.394
")
0,35 m
(13.78
")
0,15 m
(5.906
"
)
0,1 m
(3.937
")
0,05 m
(1.969
")
1
1
Fig. 54: Deviation VEGAFLEX 83 in rod version in oil
1 Dead band - no measurement possible in this area
L Probe length
Repeatability
≤ ±1 mm
Variables influencing measurement accuracy
Temperature drift - Digital output
±3 mm/10 K relating to the max. measuring range or
max. 10 mm (0.394 in)
Additional deviation through electromag-
netic interference acc. to EN 61326
< ±10 mm (< ±0.394 in)