VEGA WEIGHTRAC 31 Foundation Fieldbus User Manual
Page 48
48
7 Setup with PACTware
WEIGHTRAC 31 • Foundation Fieldbus
42375-EN-131120
Fig. 31: Set up totalizer
With this function you can activate the totalizer. As a default setting,
the totalizer is deactivated.
You can set material quantity that causes a counting pulse to be
outputted via the digital output (NPN transistor).
The leak volume suppression determines which degree of filling (in
percent) activates the totalizer.
With this you can avoid a continued summation of contamination or
slight buildup on an otherwise empty conveyor belt.
In a last step, complete the adjustment with the setup assistant. After
terminating the assistant, the program jumps back to the usual DTM
program environment.
Information:
After a successful run of the setup assistant, you have to adjust two
points in the DTM.
Setup - Totalizer (step 10)
Complete