3 Product description

POINTRAC 31 • 8/16 mA/HART - four-wire

43388-EN-131119

Avoiding mechanical shock and vibration

Storage and transport temperature see chapter "Supplement -

Technical data - Ambient conditions"

Relative humidity 20 … 85 %

3.5 Accessories and replacement parts

The display and adjustment module PLICSCOM is used for measured

value indication, adjustment and diagnosis. It can be inserted into the

sensor or the external display and adjustment unit and removed at

any time.
You can find further information in the operating instructions "Display

and adjustment module PLICSCOM" (Document-ID 27835).

The interface adapter VEGACONNECT enables the connection of

communication-capable instruments to the USB interface of a PC. For

parameter adjustment of these instruments, the adjustment software

PACTware with VEGA-DTM is required.
You can find further information in the operating instructions "Interface

adapter VEGACONNECT" (Document-ID 32628).

The VEGADIS 81 is an external display and adjustment unit for VEGA

plics

®

sensors.

For sensors with double chamber housing the interface adapter "DIS-

ADAPT" is also required for VEGADIS 81.
You can find further information in the operating instructions "VE-

GADIS 81" (Document-ID 43814).

The VEGADIS 62 is suitable for measured value indication of sensors.

It is looped into the 4 … 20 mA/HART signal cable.
You can find further information in the operating instructions "VE-

GADIS 62" (Document-ID 36469).

The electronics module PT30E.XX is a replacement part for radiation-

based sensors POINTRAC 31.
The electronics module can only be exchanged by VEGA service

technician.

3.6 Corresponding source container

A radioactive isotope in a suitable source holder is the prerequisite for

a radiation-based measurement setup.
The handling of radioactive substances is regulated by law. The radia-

tion protection rules of the country in which the system is operated

apply first and foremost.
In Germany, for example, the current radiation protection ordinance

(StrlSchV) based on the Atomic Energy Law (AtG) applies.
The following points are important for measurement with radiation-

based methods:

Storage and transport

temperature

PLICSCOM

VEGACONNECT

VEGADIS 81

External indicating unit

Electronics module