4 accessories and replacement parts – VEGA VEGAPULS 66 (≥ 2.0.0 - ≥ 4.0.0) HART and accumulator pack User Manual

Page 12

Advertising
background image

12

3 Product description

VEGAPULS 66 • HART and accumulator pack

40933-EN-121011

Transport must be carried out under consideration of the notes on the

transport packaging. Nonobservance of these instructions can cause

damage to the device.

The delivery must be checked for completeness and possible transit

damage immediately at receipt. Ascertained transit damage or con-

cealed defects must be appropriately dealt with.

Up to the time of installation, the packages must be left closed and

stored according to the orientation and storage markings on the

outside.
Unless otherwise indicated, the packages must be stored only under

the following conditions:

Not in the open

Dry and dust free

Not exposed to corrosive media

Protected against solar radiation

Avoiding mechanical shock and vibration

Storage and transport temperature see chapter "Supplement -

Technical data - Ambient conditions"

Relative humidity 20 … 85 %

3.4 Accessories and replacement parts

The indicating and adjustment module PLICSCOM is used for meas-

ured value indication, adjustment and diagnosis. It can be inserted

into the sensor and removed at any time.
You can find further information in the operating instructions "Indicat-

ing and adjustment module PLICSCOM" (Document-ID 27835).

The interface adapter VEGACONNECT enables the connection of

communication-capable instruments to the USB interface of a PC. For

parameter adjustment of these instruments, an adjustment software

such as PACTware with VEGA-DTM is required.
You can find further information in the operating instructions "Interface

adapter VEGACONNECT" (Document-ID 32628).

VEGADIS 62 is suitable for measured value indication and adjustment

of sensors with HART protocol. It is looped into the 4 … 20 mA/HART

signal cable.
You can find further information in the operating instructions "VE-

GADIS 62" (Document-ID 36469).

The protective cover protects the sensor housing against soiling and

intense heat from solar radiation.
You will find additional information in the supplementary instructions

manual "Protective cover" (Document-ID 34296).

Transport

Transport inspection

Storage

Storage and transport

temperature

Indicating and adjust-

ment module

Interface adapter

External indicating and

adjustment unit with

HART protocol

Protective cover

Advertising