2 dimensions – VEGA VEGAPULS 66 (≥ 2.0.0 - ≥ 4.0.0) HART and accumulator pack User Manual

Page 61

Advertising
background image

61

11 Supplement

VEGAPULS 66 • HART and accumulator pack

40933-EN-121011

Operating time after 10 min. charging of

0 %

> 3 h

Operating time in mode 4 (sensor per-

manently on) with completely charged

accumulator

> 60 h

Temperature range

Ʋ Charge accumulator

0 … +45° C (+32 … +167 °F)

Ʋ Accumulator operation

-20 … +60° C (-4 … +140 °F)

Temperature derating accumulator capacity

Ʋ +25° C (+77 °F)

100 %

Ʋ -10° C (+14 °F)

50 %

Electrical protective measures
Protection, depending on housing version

Ʋ Plastic housing

IP 66/IP 67

Ʋ Aluminium housing, stainless steel

housing - investment casting, stain-

less steel housing - electro-polished

IP 66/IP 68 (0.2 bar)

4)

Overvoltage category

III

Protection class

III

Approvals
Instruments with approvals can have different technical data depending on the version.
For that reason the associated approval documents of these instruments must be carefully noted.

They are part of the delivery or can be downloaded under www.vega.com and "VEGA Tools" as

well as under "Downloads" and "Approvals".

11.2 Dimensions

The following dimensional drawings represent only an extract of the possible versions. Detailed

dimensional drawings can be downloaded at www.vega.com/downloads under "Drawings".

Housing

1

~ 87 mm (3.43")

M16x1,5

ø 84 mm

(3.31")

120 mm (4.72"

)

M20x1,5/

½ NPT

Fig. 43: Dimensions housing - with integrated indicating and adjustment module the housing is 9 mm/0.35 in

higher

4)

The prerequisites for maintaining the protection rating are a suitable cable as well as correct mounting.