9 supplement, 1 technical data – VEGA VEGAFLEX series 80 - External housing User Manual

Page 14

Advertising
background image

14

9 Supplement

External housing • VEGAFLEX 80 series

46802-EN-131120

9 Supplement

9.1 Technical data

Technical data
Following you find all data deviating from the standard instrument. All other technical data are

specified in the operating instruction of the respective sensor.

General data
Material 316L corresponds to 1.4404 or 1.4435
Materials, non-wetted parts

Ʋ Sensor housing (metal housing)

316L

Ʋ Plastic instrument housing (external

housing)

plastic PBT (Polyester)

Ʋ Stainless steel instrument housing

(external housing)

316L, precision casting

Ʋ Housing base

plastic PBT (Polyester)

Ʋ Wall mounting plate

plastic PBT (Polyester)

Ʋ Seal between housing socket and wall

mounting plate

TPE (fixed connected)

Ʋ Seal between housing and housing

cover (instrument version)

Silicone

Ʋ Ground terminal

316L

Ʋ HF connection cable

PE

Ʋ Connection plug (HF connection

cable)

Cu alloy (nickle-plated)

Weight

Ʋ External instrument housing

approx. 660 g (23 oz)

Ʋ Sensor

0.4 … 2 kg (0.882 … 4.41 lbs) depending on the process

fitting

Sensor length (L)

Ʋ VEGAFLEX 81, 83, 86

see operating instructions manual of the respective

sensor

Ʋ VEGAFLEX 82

1 … 45 m (3.281 … 147.6 ft)

Length HF connection cable to external

housing

2, 5 or 10 m (6.562, 16.4, 32.81 ft)

Min. dielectric constant of the medium

Ʋ VEGAFLEX 81, 82, 83, 86

ε

r

> 1.6

Ʋ if sensor length L > cable length HF

connection cable

ε

r

> 2

Process conditions
Process pressure

depending on the process fitting

Ambient temperature - HF connection

cable

-40 … +85 °C (-40 … +185 °F)