C&H Technology PS21267-AP User Manual

Page 4

Advertising
background image

3

PS21267-P / PS21267-AP
Intellimod™ Module
Dual-In-Line Intelligent Power Module
30 Amperes/600 Volts

Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com

08/10 Rev. 01

Electrical and Mechanical Characteristics,

T

j

= 25°C unless otherwise specified

Characteristics

Symbol

Test Conditions

Min.

Typ.

Max.

Units

IGBT Inverter Sector

Collector-Emitter Cutoff Current

I

CES

V

CE

= V

CES

, T

j

= 25°C

1.0

mA

V

CE

= V

CES

, T

j

= 125°C

10

mA

Diode Forward Voltage

V

EC

T

j

= 25°C, -I

C

= 30A, V

IN

= 0V

1.5

2.0

Volts

Collector-Emitter Saturation Voltage

V

CE(sat)

I

C

= 30A, T

j

= 25°C, V

D

= V

DB

= 15V, V

IN

= 5V

1.40

1.90

Volts

I

C

= 30A, T

j

= 125°C, V

D

= V

DB

= 15V, V

IN

= 5V

1.40

1.90

Volts

Inductive Load Switching Times

t

on

0.70

1.30

1.90

µs

t

rr

V

CC

= 300V, V

D

= V

DB

= 15V,

0.30

µs

t

C(on)

I

C

= 30A, T

j

= 125°C, V

IN

= 5 ⇔ 0V,

0.40

0.60

µs

t

off

Inductive Load (Upper-Lower Arm)

2.00

2.60

µs

t

C(off)

0.65

0.90

µs

T

C

Measurement Point

T

TC

TC

HEATSINK BOUNDARY

POWER TERMINALS

CONTROL TERMINALS

Advertising