PS21267-P / PS21267-AP
Intellimod™ Module
Dual-In-Line Intelligent Power Module
30 Amperes/600 Volts

Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com

08/10 Rev. 01

Recommended Conditions for Use

Characteristic

Symbol

Condition

Min.

Typ. Max. Units

Supply Voltage

V

CC

Applied between P-N

0

300 400 Volts

Control Supply Voltage

V

D

Applied between V

P1

-V

PC

, V

N1

-V

NC

13.5

15.0 16.5 Volts

V

DB

Applied between

13.0

15.0 18.5 Volts

V

UFB

-V

UFS

,

V

VFB

-V

VFS

, V

WFB

-V

WFS

Control Supply Variation

Δ

V

D

,

Δ

V

DB

-1

1 Volts/μs

PWM Input Frequency

f

PWM

T

C

≤ 100°C, T

j

≤ 125°C

20

kHz

Allowable rms Current*

I

O

V

CC

= 300V, V

D

= V

DB

= 15V, f

PWM

= 5kHz,

19.1 Arms

PF = 0.8, Sinusoidal, T

j

≤ 125°C, T

C

≤ 100°C

V

CC

= 300V, V

D

= V

DB

= 15V, f

PWM

= 15kHz,

11.6 Arms

PF = 0.8, Sinusoidal, T

j

≤ 125°C, T

f

≤ 100°C

Minimum Input

P

WIN(on)

**

0.3

µs

Pulse Width

P

WIN(off)***

Below Rated Current

200 ≤ V

CC

≤ 350V,

1.5

µs

Between Rated Current

13.5 ≤ V

D

≤ 16.5V,

3.0

µs

& 1.7 Times of Rated Current

13.0 ≤ V

DB

≤ 18.5V,

Between 1.7 Times of Rated

-20°C ≤ T

C

≤ 100°C,

3.6

µs

& 2.0 Times of Rated Current

N-line Wiring Inductance Less Than 10nH

V

NC

Variation

V

NC

Between V

NC

-N (Including Surge)

-5.0

5.0

Volts

Arm Shoot-through

t

DEAD

For Each Input Signal, T

C

< 100°C

2

µs

Blocking Time

* The allowable rms current value depends on the actual application conditions.
**If input signal ON pulse is less than PWIN(on), the device may not respond.

***The IPM may fail to respond to an ON pulse if the preceeding OFF pulse is less than PWIN(off).