C&H Technology PS21267-AP User Manual

Page 5

Advertising
background image

4

PS21267-P / PS21267-AP
Intellimod™ Module
Dual-In-Line Intelligent Power Module
30 Amperes/600 Volts

Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com

08/10 Rev. 01

Electrical and Mechanical Characteristics,

T

j

= 25°C unless otherwise specified

Characteristics

Symbol

Test Conditions

Min.

Typ.

Max.

Units

Control Sector

Circuit Current

I

D

V

D

= V

DB

= 15V, V

IN

= 5V,

7.00

mA

Total of V

P1

-V

PC

, V

N1

-V

NC

V

D

= V

DB

= 15V, V

IN

= 0V,

7.00

mA

Total of V

P1

-V

PC

, V

N1

-V

NC

V

D

= V

DB

= 15V, V

IN

= 5V,

0.55

mA

V

UFB

-V

UFS

, V

VFB

-V

VFS

, V

WFB

-V

WFS

V

D

= V

DB

= 15V, V

IN

= 0V,

0.55

mA

V

UFB

-V

UFS

, V

VFB

-V

VFS

, V

WFB

-V

WFS

Fault Output Voltage

V

FOH

V

SC

= 0V, F

O

Circuit: 10kΩ to 5V Pull-up

4.9

Volts

V

FOL

V

SC

= 1V, I

FO

= 1mA

0.95

Volts

Input Current

I

IN

V

IN

= 5V

1.0

1.5

2.00

mA

Short-Circuit Trip Level*

V

SC(ref)

T

C

= 20 ~ 100°C, V

D

= 15V

0.45

0.52

Volts

Supply Circuit Undervoltage

UV

DBt

Trip Level, T

j

≤ 125°C

10.0

12.0

Volts

Protection

UV

DBr

Reset Level, T

j

≤ 125°C

10.5

12.5

Volts

UV

Dt

Trip Level, T

j

≤ 125°C

10.3

12.5

Volts

UV

Dr

Reset Level, T

j

≤ 125°C

10.8

13.0

Volts

Fault Output Pulse Width**

t

FO

C

FO

= 22nF

1.0

1.8

ms

ON Threshold Voltage

V

th(on)

Applied between U

P

, V

P

, W

P

-V

PC,

2.1

2.3

2.6

Volts

OFF Threshold Voltage

V

th(off)

U

N

, V

N

, W

N

-V

NC

0.8

1.4

2.1

Volts

Thermal Characteristics

Characteristic

Symbol

Condition

Min.

Typ.

Max.

Units

Junction to Fin

R

th(j-f)Q

IGBT Part (Per 1/6 Module)

1.80

°C/W

Thermal Resistance

R

th(j-f)D

FWDi Part (Per 1/6 Module)

3.00

°C/W

Contact Thermal Resistancw

R

th(c-f)

Case to Fin (Per 1 Module)

0.067

°C/W

* Short-Circuit protection is functioning only at the lower arms. Please select the value of the external shunt resistor such that the SC trip level is less than 30A.
**Fault signal is asserted when the lower arm short circuit or control supply under-voltage protective functions operate. The fault output pulse-width t

FO

depends on the capacitance value

of C

FO

according to the following approximate equation: C

FO

= (12.2 x 10

-6

) x t

FO

{F} .

Advertising