M ma aiin nt te en na an nc ce e, T tr ro ou ub bl le es sh ho oo ot tiin ng g – Velleman ASTRO-10 User Manual

Page 5

Advertising
background image

sing the RESET button and repeat the starting operations.

• Contact your supplier should any problem continue.

C

CA

AU

UT

TIIO

ON

N

• IIff iig

gn

niittiio

on

n iis

s d

diiffffiic

cu

ulltt o

orr iirrrre

eg

gu

ulla

arr b

be

effo

orre

e rre

ep

pe

ea

attiin

ng

g tth

he

e iig

gn

niittiio

on

n

o

op

pe

erra

attiio

on

ns

s m

ma

ak

ke

e s

su

urre

e tth

ha

att tth

he

e ffa

an

n iis

s n

no

ott llo

oc

ck

ke

ed

d a

an

nd

d tth

ha

att a

aiirr iin

nlle

ett

a

an

nd

d o

ou

uttlle

ett a

arre

e u

un

no

ob

bs

sttrru

uc

ctte

ed

d..

3

3..2

2 S

SW

WIIT

TC

CH

HIIN

NG

G O

OF

FF

F

• To stop the heater, shut off the gas cylinder tap. Let the fan run until the

flame shuts down and then turn the fan switch to position O.

3

3..3

3 A

AIIR

R C

CO

ON

ND

DIIT

TIIO

ON

NIIN

NG

G

• The heater can also be used as a ventilator.
• In this case remove the gas supply hose and connect the plug of the heater to a suitable electrical supply.
• Set the fan switch to position I.

4

4.. M

MA

AIIN

NT

TE

EN

NA

AN

NC

CE

E

• The repairs or maintenance operations must only be carried out by qualified personnel.
• The unit must be checked by a qualified technician at least once a year.
• Regularly check the conditions of gas hose, and gas regulator if it must be replaced only use original spare parts.
• Before starting any maintenance operation on the heater disconnect from both gas and electrical supplies.
• If the unit has not been used for a long period we advise that a technician carries out a general check up before using. It is

important to control the following:

• Periodically check the gas supply hose conditions and, should it be changed, use only original spare parts.
• Check the starting electrode position (see Fig. 6).
• Check the connections of the safety thermostat and of the thermocouple: they must always be clean.
• If necessary clean the fan blade and the inside of the heater using compressed air.

5

5.. T

TR

RO

OU

UB

BL

LE

ES

SH

HO

OO

OT

TIIN

NG

G

M

Ma

an

nu

ua

all iig

gn

niittiio

on

n m

mo

od

de

ells

s

A

Au

utto

om

ma

attiic

c iig

gn

niittiio

on

n m

mo

od

de

ells

s

2

GB

Fig. 6

The motor does not work

The motor works, but the burner
does not light up and after few
seconds the heater stops

The burner lights up but after few
seconds the
heater stops

The heater stops during operation

No electricity supply

The room thermostat is regulated too low

The safety thermostat is on

The gas cylinder tap is closed

The gas cylinder is empty

The nozzle is obstructed

The solenoid gas valve is not open

There is no spark

No connection with the earthing system

Defective connection between sensor and
safety device

Defective safety device

Excessive gas supply

Insufficient air flow

Insufficient gas supply due to ice formation on
the cylinder

Check the terminal board with a tester

Regulate the thermostat on a higher temperature

Wait about one minute and then push the RESET button

Open the tap

Use a new cylinder

Remove the nozzle and clean it

Check that that the solenoid valve works

Check the position of electrode

Check and connect properly

Check and connect properly

Replace the safety device

Check the pressure reducer and replace it if required.

Check that the motor works properly

Check and use a larger cylinder or two cylinders connected together.

PROBLEM

CAUSES

SOLUTIONS

The motor does not work

Piezo does not spark

No gas flow to the burner

The burner starts but it stops as
the gas valve is released

The heater stops during operation

No electricity supply

The motor is locked

Electrode in a wrong position

Faulty connection between piezo and electrode

The cylinder gas tap is closed

The cylinder is empty

The nozzle is obstructed

Gas leaks from the supply hose or from the tap

The thermocouple is not warm enough

The safety device works due to lack of cooling

Excessive gas supply

Insufficient air flow

Insufficient gas supply due to ice
formation on the cylinder

Check the terminal board with a tester

Unlock the motor using a tool

Check and set the electrode to the right position

Check and connect properly

Open the gas tap

Replace the cylinder

Remove the nozzle and clean it

Find leaks using approved leak detector and connect properly

Repeat the starting operation keeping the button pushed for a longer time

See point “The motor does not work”

Check the pressure reducer and if required replace it

Check that the motor works properly

Check and eventually use a larger cylinder or two cylinders connected
parallely.

PROBLEM

CAUSES

SOLUTIONS

Advertising