Important:

• Do not connect 2 wires or more directly

to a terminal. When it is necessary to
connect 2 wires or more, use a splitter.

• Connect an external device with verifying

that the ratings are within the specifica-
tions below.

r Insert the external I/O terminals plug to

the external I/O terminals on the mount-
ing side of the camera firmly.

* Make sure that the external I/O terminals

plug is inserted to the external I/O termi-
nals firmly.

<Ratings>

q ALARM IN

No-voltage make contact input (4-5 V DC
pulled up)
OFF: Open or 4-5 V DC
ON: Make contact with GND (required

drive current: 1 mA or more)

w ALARM OUT, e AUX OUT

Open collector output (external max.
applied voltage: 20 V DC)
OPEN: 4-5 V DC, internally pulled up
CLOSE: Output voltage of 1 V DC or less

(100 mA or less)

w Alarm output (

ALARM OUT)

r GND

q Alarm input (

ALARM IN)

e AUX output (

AUX OUT)