1-2

Introduction

Set-up and calibration programming is entered on front panel
membrane keys. HIGH and LOW torque limits are adjustable to
give an audible alert. The user selects TRACK mode to display
torque values as they are applied, PEAK HOLD or POWER
TOOL modes to display the highest torque value applied, or
FIRST PEAK mode which captures the torque output at the
“click” of a set-able wrench or driver. CLEAR, STORE and
PRINT functions can be set up for automatic or manual
operation.

The indicator stores and recalls up to 3000 torque/force
readings and does statistical analysis on them for downloading
to printer or computer. The statistical report (print out) includes
a simple histogram for process monitoring. True RS-232 serial
printer and separate RS-232 computer COM ports are at the
back of the unit.

The 2000-810-01 Indicator operates from the AC power line and
is switch selectable for either 120VAC or 220 VAC, 50–60 Hz.
Its integral switching power supply is UL listed. A hard-wired
lithium battery keeps the internal memory and date-time clock
operating for up to 10 years.

The information in this manual is general. Operational features,
procedures and specifications may change without notice. CDI
makes no claims as to the suitability of this information for
diverse user applications.

Advertising