E-boost-40/60 instructions – Turbosmart BOOST CONTROLLERS – ELECTRONIC - e-Boost1 (2002-05) – Complete User Manual User Manual

Page 7

Advertising
background image

e-Boost-40/60 Instructions

Page 7

PART NUMBER

FG-EBOOST-

40/60

2j. Wiring

-

The e-Boost must be connected to a 12 volt negative earth electrical system.

-

All electrical connections must be soldered.

-

Refer to the following table and diagram for detail on wiring the e-Boost.


Wire

Connect to

RED

+ 12 Volts switched through ignition – connect via 5 Amp fuse supplied

BLACK Chassis, earth or ground
GREY

Solenoid wire 1 – connect using wire supplied – polarity not important

BROWN

Solenoid wire 2 - connect using wire supplied – polarity not important

YELLOW Dimmer circuit + 12 Volts
WHITE

Auxiliary output – switched to ground – see diagram below

GREEN

External set point 2 refer to section 5d

ORANGE External set point 3 refer to section 5d




3. BASIC OPERATION

3a. Live Mode
When the e-Boost is powered up it will automatically go to Live Mode. In this Mode the readout and bar graph will display accurate Live boost
or vacuum readings. In Live Mode you can change between three boost pressure settings called boost set points. These appear on the readout
as SP1, SP2 and SP3, refer to section 4d for detail. When the e-Boost is powered up it always defaults to SP1. To change between the boost set
points simply press the up or down arrow, the set point will be displayed for one second and then the readout will return to Live boost or vacuum
readings.

3b. Boost Pressure
Boost pressures are set by entering a number in each of the three the boost set points, see section 4d for more detail. To view the boost set
point value in Live Mode press the Mode button momentarily. Press the up or down arrows to view the three different boost set point values, i.e.
SP1, SP2 or SP3. Press the Mode button twice to return to Live Mode. Note the boost set point value that was last viewed will be active.

3c. Boost Parameters
To access the boost parameter menu press and hold the Mode button and the down arrow simultaneously. The readout will begin to flash
between the selected parameter and its value, scroll up or down to the parameter you want to edit. Press and hold the Mode button for two
seconds and the parameter will begin to flash. To change the value of the parameter press the up or down arrow until the desired value appears
on the readout. To store this value press the Mode button momentarily. To exit the boost parameter menu press the Mode button again, the e-
Boost will display END as confirmation of exiting the boost parameter menu. This will return you to Live Mode.

Advertising