e-Boost-40/60 Instructions

Page 8

PART NUMBER

FG-EBOOST-

40/60

3d. User Parameters
To access the user parameter menu press and hold the Mode button and the up arrow simultaneously. The readout will begin to flash between
the selected parameter and its value, scroll up or down to the parameter you want to edit. Press and hold the Mode button for two seconds and
the parameter will begin to flash. To change the value of the parameter press the up or down arrow until the desired value appears on the
readout. To store this value press the Mode button momentarily. To exit the boost parameter menu press the Mode button again, the e-Boost
will display END as confirmation of exiting the boost parameter menu. This will return you to Live Mode.

3e. Turning the e-Boost off
To turn the e-Boost off, press and hold the Mode button for five seconds. This will revert your boost pressure back to standard, the unit is
therefore fail safe. Standard boost pressure depends on your actuator, most are approximately 0.5 bar (7 psi or 50 kpa).

To turn the e-Boost on press the Mode button momentarily, the display will light up and the e-Boost is on.

4. SETTING UP YOUR e-Boost

This section outlines how to use and program the basic parameters offered in the e-Boost, for advanced set-up refer to section 5. The diagram
pictured below indicates how the menu is structured in the e-Boost.

Up or Down Arrows

Hold the Mode button

Hold the Mode button

and press the Down arrow

and press the Up Arrow

Key:

SP1, SP2, SP3

– Boost Set Point 1,2 & 3

GP1, GP2, GP3

– Gate Pressure 1,2 & 3

SEN

– Sensitivity


AU

–Auxiliary Output

AL

– Audible Alarm

BGR

– Bar Graph Scale


OBS

– Over Boost Shutdown

PSI/KPA/BAR

– Display Units

ISP/ESP – Internal Set Point Switching
& Internal Set Point Switching

4a. Over Boost Shutdown – VERY IMPORTANT! In order to successfully program your e-Boost you MUST carefully follow this section.


The Over Boost Shutdown or OBS is a very important safety feature of the e-Boost. The OBS must
be set to a SAFE level at least 0.15 bar (2.2psi or 15kpa) above the highest boost pressure you want
to produce. The OBS is factory set to 0.48 bar (7 psi or 48 kpa), so you must enter a figure in order
for the e-Boost to produce more than standard boost pressure. The purpose of this feature is to
protect the user against accidentally entering a boost set point value that is too high, preventing a
dangerously high boost pressure. Extreme care should be taken when setting this parameter,
Turbosmart recommends that you seek advice from an appropriately qualified technician with regard
to the OBS setting.

GP3

SP 3

ISP/ESP

SP3

SP2

PSI/KPA/BAR

GP2

SP 1

OBS

SP2

BGR

GP1

AL

SP1

AU

SEN

When in Live Mode

Once

- To display boost set point values

press the Mode button

Twice

- To access Peak Hold

Three times - To clear Peak Hold

Live Mode

Boost Parameters

User Parameters