9067-OM (V4.4)

9067 PRODUCT MANUAL

3-15

Operating Instructions

9067 Function Submenu List and Descriptions

(continued)

• Sharpness Threshold Control

Adjusts the point at which sharpening rules become active. Data below
the threshold setting is passed unaffected.

Higher settings allow for a more subtle sharpness enhancement
(especially with content showing motion). Lower settings allow more
content in general to be acted upon by the enhancement process.

(Range is 0 thru 255)

• Noise Reduction Control

Adjusts the amount of statistical low-pass filtering applied to the data.
Using this control, regular pattern noise artifacts from the sharpening
process can be reduced, resulting in subjectively smoother raster
backgrounds and detail boundaries.

(Range is 0 thru 63)