Specifi cations (Extract)

EN-34

Manual | TouchMonitor TM7/TM9

Digital Inputs

HW20711:

4 AES3 inputs (transformer balanced, 110 ), 25-pin
Sub-D-F connector with 4 inputs and 4 outputs

HW20712:

4 AES3id inputs (unbalanced, 75 ), 8 BNC-F connectors
with 4 inputs and 4 outputs

HW20714:

4 AES3 inputs (transformer balanced, 110 ), 25-pin
Sub-D-F connector with 4 inputs and 4 outputs and 3G-SDI
interface with BNC-F connectors In and Through

HW20715:

8 AES3 inputs (transformer balanced, 110 ), 2 x 25-pin
Sub-D-F connector with 4 inputs and 4 outputs each

HW20911:

4 AES3 inputs (transformer balanced, 110 ), 25-pin
Sub-D-F connector with 4 inputs and 4 outputs

HW20912:

4 AES3id inputs (unbalanced, 75 ), 8 BNC-F connectors
with 4 inputs and 4 outputs

HW20913:

8 AES3 inputs (transformer balanced, 110 ), 2 x 25-pin
Sub-D-F connector with 4 inputs and 4 outputs each

HW20914:

8 AES3id inputs (unbalanced, 75 ), 16 BNC-F connectors
with 8 inputs and 8 outputs

HW20930:

3G-SDI interface with BNC-F connectors In and Through

Sampling rates:

44.1, 48, 96 kHz, synchronisation via digital input signal

Digital Outputs

HW20711:

4 AES3 outputs, 25-pin Sub-D-F connector (4 in, 4 out)

HW20712:

4 AES3id outputs, 8 BNC-F connectors (4 in, 4 out)

HW20714:

4 AES3 outputs, 25-pin Sub-D-F connector (4 in, 4 out) and
3G-SDI interface with BNC-F connectors In and Through

HW20715: 8

AES3

outputs, 2 x 25-pin Sub-D-F connector (4 in, 4 out each)

HW20911:

4 AES3 outputs, 25-pin Sub-D-F connector (4 in, 4 out)

HW20912:

4 AES3id outputs, 8 BNC-F connectors (4 in, 4 out)

HW20913: 8

AES3

outputs, 2 x 25-pin Sub-D-F connector (4 in, 4 out each)

HW20914:

8 AES3id outputs, 16 BNC-F connectors (8 in, 8 out)

Sampling rates:

referenced to digital inputs or internal clock

Basic Stereo PPM (Standard Software)

General
Input sources:

analog, digital, 3G-SDI, depending on mounted audio interface

2-ch. peakmeter:

for one installed Stereo channel pair L/R

Displays:

• Peak level

Peak

hold

• Numerical value of the display

Functions:

• Gain (+20 dB, +40 dB depending on selected standard)

• Peak hold on/off, Memory, Reset

Analog Peakmeter
Analog scales:

• DIN5: +5 .. -50 dB,

• Nordic: +12 .. -42 dB,

• BR IIa: 7 .. 1 (British),

• BR IIb: +12 .. -12 dB (British),

Integration time:

according to standard or 20 ms, 10 ms, 1 ms, 0.1 ms

Peak hold display:

1 s, 2 s, 4 s, 10 s, 20 s, 30 s, manual reset or off

Digital Peakmeter
Word width: 24 bit
Digital scales:

• TP60: +3 .. –60 dB

• Dig60: 0 .. –60 dB

• DIN5: +5 .. -50 dB,

• Nordic: +12 .. -42 dB,

• BR IIa: 7 .. 1 (British),

• BR IIb: +12 .. -12 dB (British),

Headroom/Headr. Ref:

adjustable in 1 dB steps in the range from 0 to –20 dB

Operation range:

adjustable in 1 dB steps in the range from 0 to –20 dB

Attack time:

as standard or selectable: Sample, 20 ms, 10 ms, 1 ms, 0.1 ms

British scales also 150 ms selectable

Gain:

+20 dB, +40 dB depending on selected standard

High-pass fi lter:

Off, 5 Hz, 10 Hz, 20 Hz

Peak hold display:

1 s, 2 s, 4 s, 10 s, 20 s, 30 s, manual reset or off

Over display hold time:

1 s or manual

PPM Over threshold:

Full Scale, Full Scale -1LSB, Full Scale -2LSB, –0.1 dBFS,

–0.5 dBFS, –1 dBFS, –2 dBFS, –3 dBFS

PPM Over attack time:

1 to 15 samples

PPM Over word width: 16 to 24 Bit, selectable
True Peak Over

threshold:

–1.0 dBTP, –2.0 dBTP, –3.0 dBTP, –4.0 dBTP

Advertising