Table 3. extended resolution register, Table 2. temperature data format, Table 1. conversion rate control byte – Rainbow Electronics MAX6656 User Manual
Page 11
MAX6655/MAX6656
Dual Remote/Local Temperature Sensors and
Four-Channel Voltage Monitors
______________________________________________________________________________________
11
FRACTIONAL TEMPERATURE (°C)
DIGITAL OUTPUT
0
0000 0000
0.125
0010 0000
0.250
0100 0000
0.375
0110 0000
0.500
1000 0000
0.625
1010 0000
0.750
1100 0000
0.875
1110 0000
Table 3. Extended Resolution Register
TEMP. (
°C)
ROUNDED
TEMP. (
°C)
DIGITAL
OUTPUT
130.00
+127
0 111 1111
127.00
+127
0 111 1111
126.00
+126
0 111 1111
25.25
+25
0 001 1001
0.50
+1
0 000 0001
0
0
0 000 0000
-0.625
-1
1 111 1111
-65
-65
1 011 1111
Diode Fault (Short or Open)
—
1111 1111
Table 2. Temperature Data Format
DATA
(RCRA, 04H)
WAIT TIME
BETWEEN CONVERSION
SEQUENCES (s)
00h
0
01h
0.125
02h
0.250
03h
0.500
04h
1.000
05h
2.000
06h
4.000
07h
4.000
Table 1. Conversion Rate Control Byte