Table 6. command byte register map (continued), Table 7. configuration byte 1 bit assignments – Rainbow Electronics MAX6656 User Manual

Page 14

Advertising
background image

MAX6655/MAX6656

Dual Remote/Local Temperature Sensors and
Four-Channel Voltage Monitors

14

______________________________________________________________________________________

REGISTER

ADDRESS

POR STATE

FUNCTION

RV1HL

28h

1101 0011

Read V

IN1

ALERT High Limit

RV1LL

29h

1010 1101

Read V

IN1

ALERT Low Limit

RV2HL

2Ah

1101 0011

Read V

IN2

(V

CC

)

ALERT High Limit for MAX6655 (MAX6656)

RV2LL

2Bh

1010 1101

Read V

IN2

(V

CC

)

ALERT Low Limit for MAX6655 (MAX6656)

RV3HL

2Ch

1101 0011

Read V

IN3

ALERT High Limit

RV3LL

2Dh

1010 1101

Read V

IN3

ALERT Low Limit

RV0

2Eh

0000 0000

Read V

CC

(V

IN2

) for MAX6655 (MAX6656)

RV1

2Fh

0000 0000

Read V

IN1

RV2

30h

0000 0000

Read V

IN2

(V

CC

) for MAX6655 (MAX6656)

RV3

31h

0000 0000

Read V

IN3

RSL2

32h

0000 0000

Read Status Byte 2

RCL2

33h

0000 0000

Read Configuration Byte 2

WCA2

34h

N/A

Write Configuration Byte 2

RDID

FEh

0000 1010

Read Device ID

RDRV

FFh

0100 1101

Read Manufacture ID

Table 6. Command Byte Register Map (continued)

BIT

NAME

POR

STATE

FUNCTION

7 (MSB)

Mask All

0

Masks out all

ALERT interrupts if high.

6

RUN/STOP

0

Standby mode control bit; if high, the device immediately stops converting and
enters standby mode. If low, the device enters normal conversion mode.

5

Mask Remote

Temperature 1

0

High masks out

ALERT interrupts due to remote-diode 1.

4

Mask Remote

Temperature 2

0

High masks out

ALERT interrupts due to remote-diode 2.

3

Mask V

IN3

0

High masks

ALERT interrupts due to V

IN3

.

2

Mask V

IN2

0

High masks

ALERT interrupts due to V

IN2

(V

CC

) for MAX6655 (MAX6656).

1

Mask V

IN1

0

High masks

ALERT interrupts due to V

IN1

.

0

Mask V

CC

0

High masks

ALERT interrupts due to V

CC

(V

IN2

) for MAX6655 (MAX6656).

Table 7. Configuration Byte 1 Bit Assignments

Note 1: Upon application of power, the ADC begins converting. The MSB of the Status Byte register indicates a conversion in
progress. The Status Byte has a value of 80h during conversions and a value of 00h between conversions. Therefore, at power-on,
the Status Byte alternates between 00h and 80h.