15

BIT

NAME

POR

STATE

FUNCTION

7 (MSB)

Disable Remote

Temperature 1

Measurement

0

If high, the remote temperature 1 measurement is disabled.

6

Disable Remote

Temperature 2

Measurement

0

If high, the remote temperature 2 measurement is disabled.

5

Disable Internal

Temperature

Measurement

0

If high, the internal temperature measurement is disabled.

4

Disable V

IN3

Measurement

0

If high, the input voltage V

IN3

measurement is disabled.

3

Disable V

IN2

Measurement

0

If high, the input voltage V

IN2

(V

CC

) measurement is disabled for MAX6655

(MAX6656).

2

Disable V

IN1

Measurement

0

If high, the input voltage V

IN1

measurement is disabled.

1

Disable V

CC

Measurement

0

If high, the input voltage V

CC

(V

IN2

) measurement is disabled for MAX6655

(MAX6656).

0

Reserved

0

Reserved for future use.

Table 8. Configuration Byte 2 Bit Assignments

BIT

NAME

POR STATE

FUNCTION

7 (MSB)

BUSY

0

ADC is busy converting when high.

6

LHIGH

0

Internal high-temperature

ALERT has tripped when high; cleared by POR or

readout of the entire Status Byte.

5

LLOW

0

Internal low-temperature

ALERT has tripped when high; cleared by POR or

readout of the entire Status Byte.

4

RHIGH

0

External 1 high-temperature

ALERT has tripped when high; cleared by POR or

readout of the entire Status Byte.

3

RLOW

0

External 1 low-temperature

ALERT has tripped when high; cleared by POR or

readout of the entire Status Byte.

2

DODS1

0

A high indicates external diode 1 open/short.

1

R2HIGH

0

External 2 high-temperature

ALERT has tripped when high; cleared by POR or

readout of the entire Status Byte.

0

R2LOW

0

External 2 low-temperature

ALERT has tripped when high; cleared by POR or

readout of the entire Status Byte.

Table 9. Status Byte 1 Bit Assignments