Max6900 i, C-compatible rtc in a tdfn, Table 3. data transfer summary – Rainbow Electronics MAX6900 User Manual

Page 11

Advertising
background image

MAX6900

I

2

C-Compatible RTC in a TDFN

______________________________________________________________________________________

11

Table 3. Data Transfer Summary

BIT 7…………….……………… BIT 0 ACK BIT BIT 7…………….…………………BIT ACK BIT

8_BIT DATA

AS

BIT 7…….…….…………BIT 0 ACK BIT

7-BIT SLAVE ID

0

A

S

1

ADDR.

0A

S

R

ADDRESS/COMMAND BYTE

S

P

SINGLE WRITE

SINGLE READ

BURST WRITE

BURST READ

BIT 7…………….……….BIT 0 ACK BIT

BIT 7………….…………BIT 0

ACK BIT

BIT 7…………….……………BIT 0 ACK BIT

8_BIT DATA

/AM

BIT 7…….…………BIT 0 ACK BIT

7-BIT SLAVE ID

0A

S

1

1

ADDR.

AS

S

R

7-BIT SLAVE ID

1A

S

ADDRESS/COMMAND BYTE

S

P

FIRST 8_BIT DATA

BIT 7…………….…………BIT 0 ACK BIT

BIT 7…………….…………BIT 0 ACK BIT

BIT 7…………….………BIT 0 ACK BIT BIT 7…………….……………BIT 0 ACK BIT

ADDRESS/COMMAND BYTE

AS

7-BIT SLAVE ID

0

A

S

0

11111

1

A

S

LAST 8_BIT DATA

AS

P

S

BIT 7……….……………BIT 0 ACK BIT

BIT 7……….…………………BIT 0 ACK BIT

LAST 8_BIT DATA

/AM

SLAVE ID: 1010000

ADDR: 5-BIT RAM OR REGISTER ADDRESS

R: RAM/REGISTER SELECTION BIT. R = 0 WHEN REGISTER IS SELECTED, R = 1 WHEN RAM IS SELECTED

S: 2-WIRE BUS START CONDITION BY MASTER

P: 2-WIRE BUS STOP CONDITION BY MASTER

AS: ACKNOWLEDGE BY SLAVE

AM: ACKNOWLEDGE BY MASTER

/AM: NO ACKNOWLEDGE BY MASTER

BIT 7…………….………… BIT 0 ACK BIT

7-BIT SLAVE ID

0

A

S

1

11111

1

A

S

7-BIT SLAVE ID

1

A

S

FIRST 8_BIT DATA

AM

BIT 7…………….…………… BIT 0 ACK BIT

ADDRESS/COMMAND BYTE

S

S

P