Table 3. command byte register bit assignment – Rainbow Electronics MAX6622 User Manual

Page 11

Advertising
background image

cases, the alert is cleared even if the fault condition
exists, but the

ALERT output reasserts at the end of the

next conversion. The bits indicating the fault for the
OVERT interrupt output clear only on reading the status 2
register even if the fault conditions still exist. Reading the

status 2 register does not clear the

OVERT interrupt out-

put. To eliminate the fault condition, either the measured
temperature must drop below the temperature threshold
minus the hysteresis value (4°C), or the trip temperature
must be set at least 4°C above the current temperature.

MAX6622

5-Channel Precision Temperature Monitor

______________________________________________________________________________________

11

REGISTER

ADDRESS

(hex)

POR STATE

(hex)

READ/

WRITE

DESCRIPTION

Local

07

00

R

Read local temperature register

Remote 1

01

00

R

Read channel 1 remote temperature register

Remote 2

02

00

R

Read channel 2 remote temperature register

Remote 3

03

00

R

Read channel 3 remote temperature register

Remote 4

04

00

R

Read channel 4 remote temperature register

Configuration 1

41

00

R/W

Read/write configuration register 1

Configuration 2

42

00

R/W

Read/write configuration register 2

Configuration 3

43

00

R/W

Read/write configuration register 3

Status1

44

00

R

Read status register 1

Status2

45

00

R

Read status register 2

Status3

46

00

R

Read status register 3

Local ALERT High Limit

17

5A

R/W

Read/write local alert high-temperature threshold limit register

Remote 1 ALERT High Limit

11

6E

R/W

Read/write channel 1 remote-diode alert high-temperature
threshold limit register

Remote 2 ALERT High Limit

12

7F

R/W

Read/write channel 2 remote-diode alert high-temperature
threshold limit register

Remote 3 ALERT High Limit

13

64

R/W

Read/write channel 3 remote-diode alert high-temperature
threshold limit register

Remote 4 ALERT High Limit

14

64

R/W

Read/write channel 4 remote-diode alert high-temperature
threshold limit register

Remote 1 OVERT High Limit

21

6E

R/W

Read/write channel 1 remote-diode overtemperature threshold
limit register

Remote 4 OVERT High Limit

24

7F

R/W

Read/write channel 4 remote-diode overtemperature threshold
limit register

Remote 1 Extended
Temperature

09

00

R

Read channel 1 remote-diode extended temperature register

Manufacturer ID

0A

4D

R

Read manufacturer ID

Table 3. Command Byte Register Bit Assignment