Table 6. configuration 3 register – Rainbow Electronics MAX6622 User Manual

Page 12

Advertising
background image

MAX6622

5-Channel Precision Temperature Monitor

12

______________________________________________________________________________________

Table 6. Configuration 3 Register

BIT

NAME

POR

STATE

FUNCTION

7 (MSB)

Reserved

0

6

Reserved

0

5

Reserved

0

4

Reserved

0

3

Mask OVERT 4

0

Channel 4 Remote-Diode OVERT Mask Bit. Set to logic 1 to mask channel 4
OVERT.

2

Reserved

0

1

Reserved

0

0

Mask OVERT 1

0

Channel 1 Remote-Diode OVERT Mask Bit. Set to logic 1 to mask channel 1
OVERT.

BIT

NAME

POR

STATE

FUNCTION

7 (MSB)

STOP

0

Standby Mode Control Bit. If STOP is set to logic 1, the MAX6622 stops
converting and enters standby mode.

6

POR

0

Reset Bit. Set to logic 1 to put the device into its power-on state. This bit is self-
clearing.

5

TIMEOUT

0

Timeout Enable Bit. Set to logic 0 to enable SMBus timeout.

4

Fast remote 1

0

Channel 1 Fast Conversion Bit. Set to logic 1 to enable fast conversion of
channel 1.

3

Resistance

cancellation

0

Resistance Cancellation Bit. When set to logic 1, the MAX6622 cancels series
resistance in the channel 1 thermal diode.

2

Reserved

0

1

Reserved

0

0

Reserved

0

Table 4. Configuration 1 Register

Table 5. Configuration 2 Register

BIT

NAME

POR

STATE

FUNCTION

7 (MSB)

Reserved

0

6

Mask Local ALERT

0

Local Alert Mask. Set to logic 1 to mask local channel ALERT.

5

Reserved

0

4

Reserved

0

3

Mask ALERT 4

0

Channel 4 Alert Mask. Set to logic 1 to mask channel 4 ALERT.

2

Mask ALERT 3

0

Channel 3 Alert Interrupt Mask. Set to logic 1 to mask channel 3 ALERT.

1

Mask ALERT 2

0

Channel 2 Alert Mask. Set to logic 1 to mask channel 2 ALERT.

0

Mask ALERT 1

0

Channel 1 Alert Mask. Set to logic 1 to mask channel 1 ALERT.

Advertising