PMBus 6-Channel Power-Supply Manager

MAX34440

23

Table 7. Page Commands

PMBus Commands

A summary of the PMBus commands supported by the device are described in the following sections.

PAGE (00h)

The device can control up to six power supplies and up to eight temperature sensors using one PMBus (I

2

C) address.

Send the PAGE command with data 0 to 13 to select which power supply or which temperature sensor is affected by
all the PMBus commands shown in Table 1. Not all commands are supported within each page. If an unsupported
command is received, the CML status bit is set. Some commands are common, meaning that any selected page has
the same effect on and the same response from the device.

PAGE (DEC)

ASSOCIATED CONTROL

0

Power Supply Connected to ADC 0

1

Power Supply Connected to ADC 1

2

Power Supply Connected to ADC 2

3

Power Supply Connected to ADC 3

4

Power Supply Connected to ADC 4

5

Power Supply Connected to ADC 5

6

Internal Temperature Sensor

7

External DS75LV Temperature Sensor with Address 0

8

External DS75LV Temperature Sensor with Address 1

9

External DS75LV Temperature Sensor with Address 2

10

External DS75LV Temperature Sensor with Address 3

11

External MAX6695 Local Temperature Sensor

12

External MAX6695 Remote Diode 1 Temperature Sensor

13

External MAX6695 Remote Diode 2 Temperature Sensor

14 to 254

Reserved

255

Applies to All Pages