Rf02 – Rainbow Electronics RF02 User Manual

Page 14

Advertising
background image

RF02

5. Power Setting Command

bit 7 6 5 4 3

2 1

0

POR

1 0 1 1 0

p2 p1 p0 B0h

2

p1

p0

Output Power [dB]

0

0

0

0

0

0

1

-3

0

1

0

-6

0

1

1

-9

1

0

0

-12

1

0

1

-15

1

1

0

-18

1

1

1

-21

The output power is given in the table

as relative to the maximum available

power, which depends on the actual

antenna impedance.

6. Low Battery Detector and TX Bit Synchronization Command

bit 15 14 13 12 11 10 9

8

7 6

5 4 3 2 1 0 POR

1 1 0 0 0 0 1

0

dwc

0

ebs

t4

t3

t2

t1

t0

C200h

Bit 7 <dwc> Disables the Wake-up timer periodical (every 30 second) calibration if this bit is set.

Bit 5 <ebs> Enables the TX bit synchronization circuit. The data rate must be set by the Data Rate

Command.5

The 5-bit value T of <t4 : t0> determines the threshold voltage V

lb

of the detector:

V

lb

= 2.2 V + T * 0.1 V

7. Sleep Command

bit 15 14 13 12 11 10 9

8

7 6 5 4 3 2 1 0 POR

1 1 0 0 0 1 0

0

s7

s6

s5

s4

s3

s2

s1

s0

C400h

The effect of this command depends on the Power Management Command. It immediately disables the

power amplifier (if a0=1 and ea=0) and the synthesizer (if a1=1 and es=0). Stops the crystal oscillator

Tel: +86-755-86096587 Fax: +86-755-86096602 E-mail: [email protected] http://www.hoperf.com