Rf02 – Rainbow Electronics RF02 User Manual

Page 16

Advertising
background image

RF02

Data Transmit Sequence Through the SDI Pin

Note:

Do not send CLK pulses with the TX data bits, otherwise they will be interpreted as commands.

This mode is not SPI compatible.

If the crystal oscillator and the PLL are running, the t

sx

+t

sp

delay is not needed.

10 . Status Register Read Command

bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

POR

1

1

0

0

1

1

0

0

0

0

0

0

0

0 0 0

--

With this command, it is possible to read the chip’s status register through the nIRQ pin. This command

clears the last serviced interrupt and processing the next pending one will start (if there is any).

Status Register Read Sequence

11. PLL Setting Command

PLL bandwidth can be selected by this command

PLL command

Max data rate

[kbps]

Phase noise at 1MHz offset

[dbc/Hz]

Comments

D240h 19.2 -112

25%current

D2C0h 38.4 -110

33%current

D200h 68.9 -107

50%current

D280h 115.2 -102

100%current

Tel: +86-755-86096587 Fax: +86-755-86096602 E-mail: [email protected] http://www.hoperf.com