Rainbow Electronics MAX5971А User Manual

Page 17

Advertising
background image

______________________________________________________________________________________ 17

MAX5971A

Single-Port, 40W, IEEE 802.3af/802.3at PSE

Controller with Integrated MOSFET

Overcurrent Protection

The MAX5971A has an internal sense resistor, R

SENSE

(see the Simplified Diagram), connected between the
source of the internal MOSFET and V

EE

to monitor the

load current. Under normal operating conditions, the
current through R

SENSE

(I

RSENSE

) never exceeds the

threshold I

LIM

. If I

RSENSE

exceeds I

LIM

, an internal

current-limiting circuit regulates the gate voltage of the
internal MOSFET, limiting the current. During transient
conditions, if I

RSENSE

exceeds I

LIM

by more than 2A, a

fast pulldown circuit activates to quickly recover from the
current overshoot.
In the normal powered state, the MAX5971A checks for
overcurrent conditions, as determined by I

CUT

= ~88%

of I

LIM

. The t

FAULT

counter sets the maximum allowed

continuous overcurrent period. This timer is incremented
both in startup and in normal powered state, but under
different conditions. During startup, the counter increas-
es when I

RSENSE

exceeds I

LIM

, while in the normal pow-

ered state the counter increases when I

RSENSE

exceeds

I

CUT

. It decreases at a slower pace when I

RSENSE

drops below I

LIM

or I

CUT

. A slower decrement for the

t

FAULT

counter allows for detection of repeated short-

duration overcurrent events. When the counter reaches

the t

FAULT

limit, the MAX5971A powers down the port.

For a continuous overstress, a fault occurs exactly after
a period of t

FAULT

.

After a power-off due to an overcurrent fault, the t

FAULT

timer is not immediately reset but starts decrementing.
The MAX5971A allows the port to be powered on only
when the t

FAULT

counter reaches zero. This feature sets

an automatic port power duty-cycle protection to the
internal MOSFET to avoid overheating.
In the normal powered state, the I

LIM

and I

CUT

thresh-

olds are set automatically according to the classification
result (see Table 2 for classification results based on
detection current, and the Electrical Characteristics table
for the corresponding thresholds). During startup, I

LIM

is

always set to 420mA regardless of the detected class.

Foldback Current

During startup and normal operation, an internal circuit
senses the port voltage and reduces the current-limit
value and the overcurrent threshold when (V

AGND

-

V

OUT

) < 27V. The foldback function helps to reduce the

power dissipation on the internal MOSFET. The current
limit eventually reduces down to I

TH_FB

when (V

AGND

-

V

OUT

) < 10V (see Figure 3).

Figure 3. Foldback Current Characteristics

V

AGND

- V

OUT

I

LIM

I

TH_FB

10V

27V

I

RSENSE

Advertising