4 spi serial programming characteristics – Rainbow Electronics ATmega64M1 User Manual

Page 308

Advertising
background image

308

8209A–AVR–08/09

ATmega16M1/32M1/64M1

Note:

a = address high bits, b = address low bits, H = 0 - Low byte, 1 - High Byte, o = data out, i = data in, x = don’t care

28.10.4

SPI Serial Programming Characteristics

For characteristics of the SPI module, see

“SPI Serial Programming Characteristics” on page

308

.

Write EEPROM Memory

1100 0000

000x xxaa

bbbb bbbb

iiii iiii

Write data i to EEPROM memory at
address a:b.

Load EEPROM Memory
Page (page access)

1100 0001

0000 0000

0000 00bb

iiii iiii

Load data i to EEPROM memory page
buffer. After data is loaded, program
EEPROM page.

Write EEPROM Memory
Page (page access)

1100 0010

00xx xxaa

bbbb bb00

xxxx xxxx

Write EEPROM page at address a:b.

Read Lock bits

0101 1000

0000 0000

xxxx xxxx

xxoo oooo

Read Lock bits. “0” = programmed, “1”
= unprogrammed. See

Table 28-1 on

page 289

for details.

Write Lock bits

1010 1100

111x xxxx

xxxx xxxx

11ii iiii

Write Lock bits. Set bits = “0” to
program Lock bits. See

Table 28-1 on

page 289

for details.

Read Signature Byte

0011 0000

000x xxxx

xxxx xxbb

oooo oooo

Read Signature Byte o at address b.

Write Fuse bits

1010 1100

1010 0000

xxxx xxxx

iiii iiii

Set bits = “0” to program, “1” to
unprogram. See Table XXX on page
XXX
for details.

Write Fuse High bits

1010 1100

1010 1000

xxxx xxxx

iiii iiii

Set bits = “0” to program, “1” to
unprogram. See

Table 28-6 on page

292

for details.

Write Extended Fuse Bits

1010 1100

1010 0100

xxxx xxxx

xxxx xxii

Set bits = “0” to program, “1” to
unprogram. See

Table 28-4 on page

290

for details.

Read Fuse bits

0101 0000

0000 0000

xxxx xxxx

oooo oooo

Read Fuse bits. “0” = programmed, “1”
= unprogrammed. See Table XXX on
page XXX
for details.

Read Fuse High bits

0101 1000

0000 1000

xxxx xxxx

oooo oooo

Read Fuse High bits. “0” = pro-
grammed, “1” = unprogrammed. See

Table 28-6 on page 292

for details.

Read Extended Fuse Bits

0101 0000

0000 1000

xxxx xxxx

oooo oooo

Read Extended Fuse bits. “0” = pro-
grammed, “1” = unprogrammed. See

Table 28-4 on page 290

for details.

Read Calibration Byte

0011 1000

000x xxxx

0000 0000

oooo oooo

Read Calibration Byte

Poll RDY/BSY

1111 0000

0000 0000

xxxx xxxx

xxxx xxxo

If o = “1”, a programming operation is
still busy. Wait until this bit returns to
“0” before applying another command.

Table 28-18. Serial Programming Instruction Set (Continued)

Instruction

Instruction Format

Operation

Byte 1

Byte 2

Byte 3

Byte4