10

5429B–IMAGE–04/05

ATMOS -1M60/1M30 [Preliminary]

• Readout of dummy frames (to prevent against large dark current integration) while the

camera waits for the next trigger event

The integration delay is a few µs. The minimum pulse duration is 1µs. The source of ITC signal
is selectable between CameraLink CC1 signal and TTL_IO trigger input. See Register Mode
Control @ 204H Internal Register Mappingon on

page 17

The period is defined by the ITC signal period.

As the integration time is not the same for all lines (in the following timing diagram line n integra-
tion time is greater than line 1 integration time) this mode must be used with a pulsed light
source or a shutter element. Moreover any residual light when shutter output signal is inhibited
must be avoided. The exposure time is defined by the ITC signal high state time and all the lines
are exposed during the same time

Figure 4-5.

ITC Mode Chronogram

4.2

Ouput Data Timing

Line 1 Reset

Line 1

Integration

(Frame N)

Frame N

Readout

Line n

Integration

(Frame N)

Line n Reset

Line 1 Readout

and Reset

Trigger N Event

ITC in

Shutter Time

Shutter out

Trigger Delay

FVAL

Line n Readout

and Reset

Table 4-4.

Timing Values

Label

Description

Min

Typ

Max

Ts

Input setup to clock delay

1ns

Th

Output hold from clock delay

1ns